ciao, did you by any chance manage to solve it? I have the same error 2120, the fuses are fine. I have two COK-002 boards (but the second one has about ten different errors) with which I can exchange components, I tried changing the capacitors near the F6302 but nothing changed
most of the time the 1002 error is due to faulty tokens on the RSX. By removing the old capacitors and putting in tantalum ones you have a good chance of solving the problem. Remember to create bridges between the two positive areas as in the image above. NOTE: for the ground side you must...
Hi, I have a CECHC with GLOD with multiple A0202120 and some A0802020 error. Fuses, 1.7V_MISC, 1.5V_YC_RC_VDDIO are OK.
any idea?
errlog
ofst[ 12]:err_code:0xffffffff, clock:0x0b51cf8c 2006/01/07 01:02:04
ofst[ 16]:err_code:0xa0202120, clock:0x0b51cf8c 2006/01/07 01:02:04
ofst[...